APPLICATIONS:
These double screened cables are used as signal transmission cables in industrial applications. These can be easily used with their flexible construction in narrowapplications like: electronic control systems of computer or audio systems or in communication sector, electronic circuits, measurement devices, machine design,office equipment, etc. These used for indoor applications. Screening protects the cable from the outer electrical effects.
CONSTRUCTION:
Conductor | Stranded Electrolytic Annealed Copper (IEC/BS/EN 60228, VDE 0295 Class 5, 0.34mm²: Column 2) |
Insulation | PVC (BS/EN 50290-2, VDE 0207 TI2), Color Code : DIN 47100 |
Lay-up | Cores stranded in layers |
Screen | Tinned Copper Wire Braiding |
Shielding | AL-PES tape |
Outer Sheath | PVC (BS/EN 50290-2) Outer Sheath Color : RAL 7001 Grey |
Reference Standards | VDE 0812 |
Flame Test | IEC/EN/BS/DIN 60332-1-2 (VDE 0482-332-1-2) |
Technical & Electrical Properties (20°C)
Operating Voltage | 0.14 mm²...0.25 mm² | 250 V |
0.34 mm²...1.50 mm² | 300 V / 500 V | |
Test Voltage | 0.14 mm²...0.25 mm² | 1200 V |
0.34 mm²...1.00 mm² | 1500 V | |
1.50 mm².... | 2500 V | |
Insulation Resistance | Min. 200 M.Ohm x Km | |
Inductance | Approx. 0.65 mH / Km | |
Current Carrying Capacity | See Technical Data Table 4 | |
Temperature Range | Fixed | -30°C... + 70°C |
Flexible | -5°C... + 70°C | |
Minimum Bending Radius | Fixed | 7.5 x Cable Diameter |
Flexible | 15 x Cable Diameter |
Cross Section | Conductor Resistance (Max. Ω/Km) | Capacitance (Core/Core nF/Km) | Capacitance (Core/Screen nF/Km) |
---|---|---|---|
0.14 mm² | 138.0 | 80 | 120 |
0.22 mm² | 85.0 | 100 | 150 |
0.25 mm² | 77.8 | 100 | 150 |
0.34 mm² | 56.0 | 100 | 150 |
0.50 mm² | 39.0 | 110 | 170 |
0.75 mm² | 26.0 | 110 | 170 |
1.00 mm² | 19.5 | 120 | 180 |
1.50 mm² | 13.3 | 120 | 180 |